BS EN IEC 63171-1-2020 Connectors for electrical and electronic equipment Part 1: Detail specification for two-way, shielded or unshielded, free and fixed connectors一Mechanical mating information, pin assignment and additional requirements for Type 1 copper LC style.
This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors for data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C. It is intended to specify the common dimensions, mechanical, electrical, signal integrity, environmental characteristics, reliability specifications and corresponding tests for these connectors.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the reference document (including any amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary (1EV) — Chapter 581:Electromechanical components for electronic equipment
IEC 60068-1, Environmental testing — Part I: General and guidance
IEC 60512-1, Connectors for electrical and electronic equipment — Tests and measurements — Part 1: Generic specification
IEC 60512-1-1, Connectors for electronic equipment — Tests and measurements — Part 1-1:General examination — Test Ia: Visual examination
IEC 60512-1-2, Connectors for electronic equipment — Tests and measurements Part 1-2:General examination — Test Ib: Examination of dimension and mass
IEC 60512-2-1, Connectors for electronic equipment — Tests and measurements — Part 2-1:Electrical continuity and contact resistance tests — Test 2a: Contact resistance — Millivolt level method
IEC 60512-2-5, Connectors for electronic equipment — Tests and measurements — Part 2-5:Electrical continuity and contact resistance tests — Test 2e: Contact disturbance
IEC 60512-3-1, Connectors for electronic equipment — Tests and measurements — Part 3-1:
Insulation tests — Test 3a: Insulation resistance
IEC 60512-4-1, Connectors for electronic equipment — Tests and measurements — Part 4-1:Voltage stress tests — Test 4a: Voltage proof
IEC 60512-5-2, Connectors for electronic equipment — Tests and measurements — Part 5-2:Current-carrying capacity tests — Test 5b: Current-temperature derating
IEC 60512-6-4, Connectors for electronic equipment — Tests and measurements — Part 6:Dynamic stress tests — Section 5: Test 6d: Vibration (sinusoidal)
IEC 60512-9-1. Connectors for electronic equipment — Tests and measurements — Part 9-1:Endurance tests — Test 9a: Mechanical operation
IEC 60512-11-7, Connectors for electronic equipment — Tests and measurements — Part 11-7:Climatic tests — Test I Ig: Flowing mixed gas corrosion test
IEC 60512-11-12, Connectors for electronic equipment — Tests and measurements — Part 11- 12: Climatic tests — Test urn: Damp heat, cyclic
IEC 60512-13-2, Connectors for electronic equipment — Tests and measurements — Part 13-2:Mechanical operation tests — Test 13b: Insertion and withdrawal forces
IEC 60512-15-6, Connectors for electronic equipment — Tests and measurements — Part 15-6:Connector tests (mechanical) — Test 15f: Effectiveness of connector coupling devices
IEC 605 12-25-9, Connectors for electronic equipment — Tests and measurements — Part 25-9:Signal integrity tests — Test 251: Alien crosstalk
IEC 60512-26-100, Connectors for electronic equipment — Tests and measurements — Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 — Tests 26a to 26g.BS EN IEC 63171-1 pdf download.