5.1.6
An adhesive that has been investigated in accordance with the applicable requirements of CSA C22.2
No. 0.15 may secure a metal foil reflecting surface or a laminated reflecting surface to the reflector base
material.
5.2 Metal thickness
5.2.1
Metal parts of a retrofit kit and those portions of a luminaire affected by installation of the reflector kit
shall comply with the requirements for metal thickness for enclosures of Clause 5.5 in
CSA C22.2 No. 250.0.
5.2.2
When a luminaire reflector is used as an electrical enclosure or a part of it, the reflector thickness shall comply with Clause 5.5 of CSA C22.2 No. 250.0.
5.3 Polymeric materials
5.3.1
Polymeric parts of a retrofit kit that complete an enclosure as required in Clause 5.3 of CSA C22.2 No. 250.0, or that provide structural support for any electrical or non-electrical component, shall comply with the requirements for polymeric materials of Clause 5.7 in CSA C22.2 No. 250.0. Parts providing structural support for non-electrical components that weigh less than 85 g are not required to comply.
5.3.2
Metallized polymeric parts coated with an electrically conductive material shall comply with the metallized polymeric parts coating adhesion test of Clause 16.11 in CSA C22.2 No. 250.0 if they are situated above or spaced to within 75 mm (3 in) of a lampholder, lamp pin, uninsulated live part, conductor, or other electrical component.
5.4 Retrofit kits for air-handling luminaires
The combination of a retrofitted luminaire with the installation of a retrofit kit installed in accordance
with the installation instructions of the kit shall comply with requirements for air-handling luminaires of
Clause 12.2 in CSA C22.2 No. 250.0.
6 Electrical construction
6.1 Bonding and grounding
Except as permitted in Clauses 6.1.2 and 6.1.3 of this Standard, grounding and bonding of a retrofit kit shall comply with CAN/CSA-C22.2 No. 0.4 and Clause 6.14 of CSA C22.2 No. 250.0.CSA C22.2 No.250.1 pdf download.