AS NZS 5263.1.3:2021(+A1-2021) Gas appliances Part 1.3: Gas space heating appliances.
1.3 Terms and definitions
For the purposes of this Standard the terms and definitions given in AS/NZS 5263.0 and the following apply.
1.3.201
console appliance
appliance designed to be mounted on or against a wall and not built into a fireplace or cavity
1.3.202
convection heater
appliance with an effective output of heated air
1.3.203
emission class
classification of appliances based on the emission rate of NO2
1.3.203.1
emission class 0
having an NO2 emission rate into the room of 0 ng/J
1.3.203.2
emission class 1
having an NO2 emission rate into the room of less than or equal to 2.5 ng/j
1.3.203.3
emission class 2
having an NO2 emission rate into the room greater than 2.5 ng/J, but less than or equal to 5 ng/J
1.3.203.4
emission class NT
classification for an indoor flueless appliance which has not been tested for NO2 emissions or with an NO2 emission rate greater than 5 ng/J
1.3.204
radiant convection heater
appliance with an effective output of both radiation and heated air
1.3.205
radiant heater
appliance with an effective output mainly in the form of radiation
1.3.206
space heater
appliance whose primary function is to heat the space in which it is installed through radiant or convective heat or a combination of both
1.3.207
wall furnace
convection heater that is installed either between the wall studs or on the surface of the wall to heat the space in which it is installed
1.4 Test methods
The modified and new test methods applicable for this Standard are located in the following appendices; apart from these, the test methods of AS/NZS 5263.0 apply.
Appendix ZA — Preliminary test methods (applicable for Section 3)
There are no modifications or new methods for this Standard. Preliminary test methods from AS/NZS 5263.0 apply as set out in Section 3.
Section 2 Design and construction
2.1 Scope
This Clause of AS/NZS 5263.0 applies.
2.2 General design requirements
This Clause of AS/NZS 5263.0 applies, except as modified below.
2.2.13 Design of appliance base Not applicable.
2.2.10 1 Fuel storage container
The appliance shall not incorporate or have provision for a fuel storage container.
2.2.10 2 Surface finish of primary guard
All exposed surfaces of a primary guard shall be smoothly finished to prevent the possibility of abrasion or laceration to the user, or snagging of clothing.
2.3 Materials
This Clause of AS/NZS 5263.0 applies.
2.4 Design for assembly and installation.AS NZS 5263.1.3 pdf download.