AS 5341:2021 LED lamps一Test methods一Energy and functional performance.
Section 5 Measurement of photometric and colorimetric quantities
5.1 General
The measurements of luminous flux, luminous efficacy and luminous intensity distribution of LED lamps require the use of absolute photometry methods.
Alternative means of conformance to measurement of photometric and colorimetric quantities as set out in this section are provided in Table A.2.
5.2 Luminous flux
5.2.1 Total luminous flux
The measurement of total luminous flux of the device under test shall be as set out in CIE
S 025/E:2015 Clause 6.2.
5.2.2 Partial luminous flux
The test for the measurement of partial luminous flux is conducted for the desired cone angle, a, as set out in CIE S 025/E:2015 Clause 6.3.
NOTE 1 Refer to CIE TN 010 for guidance on angular intervals for luminous intensity measurements and methodology for coordinate transformation for alignment to the optical axis of the device under test.
NOTE 2 Particular energy efficiency regulations and programs use the metric “useful luminous flux when stating the luminous flux which is to be measured for lighting products.
An example of the use of this metric is in European Commission Regulations: for directional LED lamps with beam angle  90°, the useful luminous flux is the flux emitted in a solid angle of u sr (corresponding to a cone with angle of 120°); and for directional LED lamps with beam angle <90°, the useful luminous flux is the flux emitted in a solid angle of 0.5861T sr (corresponding to a cone with angle of 90°). Where measurement of partial luminous flux is required, the applicant should request the desired cone angle, a. This should be clearly reported in the test report. 5.3 Luminous efficacy 5.4 Luminous intensity distribution The measurement of luminous intensity distribution of the device under test and presentation of data shall be as set out in CIE S 025/E:2015 Clause 6.5. 5.5 Centre beam intensity and beam angles The determination of centre beam intensity and beam angle(s) of the device under test shall be as set out in CIE S 025/E:2015 Clause 6.6. 5.6 Measurement of colour quantities The measurement and determination of the colour quantities: chromaticity coordinates, correlated colour temperature, colour rendering indices, and distance from Planckian locus of the device under test shall be as set out in CIE S 025/E:2015 Clause 7.AS 5341 pdf download.